Glossary
Term | Main definition |
---|---|
Electrostatic discharge (ESD) |
A problem that exists when two items with dissimilar
static electrical charges are brought together. The static
electricity jumps to the item with lower electrical charge,
which causes ESD; ESD can damage electrical and computer
components.
Hits - 1022
|
Emitter |
A source of optical power.
Hits - 1086
|
Encoding |
Converting analog data into digital data by combining
timing and data information into a synchronized stream
of signals. Encoding is accomplished by representing
digital 1s and 0s through combining high- and low signal
voltage or light states.
Hits - 2544
|
End finish, Endface finish |
The quality of a fiber
Hits - 1046
|
End separation |
(1) The distance between the ends of two joined fibers.
The end separation is important because the degree of
separation causes an extrinsic loss, depending on the
configuration of the connection. (2) The separation of
optical fiber ends, usually taking place in a mechanical
splice or between two connectors.
Hits - 1153
|
End-to-end loss |
The optical signal loss experienced between the transmitter
and the detector due to fiber quality, splices, connectors,
and bends.
Hits - 1089
|
Energy density |
For radiation. Expressed in joules per square meter.
Sometimes called irradiance.
Hits - 1055
|
Entrance facility (EF) |
A room in a building where antenna, public, and private
network service cables can enter the building and be
consolidated. Should be located as close as possible to
the entrance point. Entrance facilities are often used to
house electrical protection equipment and connecting
hardware for the transition between outdoor and indoor
cable. Also called an entrance room.
Hits - 2079
|
Entrance point |
The location where telecommunications enter a building
through an exterior wall, a concrete floor slab, a rigid
metal conduit, or an intermediate metal conduit.
Hits - 1112
|
Epoxy |
A glue that cures when mixed with a catalyzing agent.
Hits - 1573
|
Epoxy-less connector |
A connector that does not require the use of epoxy to
hold the fiber in position.
Hits - 1056
|
Equal level far-end crosstalk (ELFEXT) |
ELFEXT is the name for the crosstalk signal that is measured
at the receiving end and equalized by the attenuation
of the cable.
Hits - 1303
|
Equipment cable |
Cable or cable assembly used to connect telecommunications
equipment to horizontal or backbone cabling
systems in the telecommunications room and equipment
room. Equipment cables are considered to be outside the
scope of cabling standards.
Hits - 1379
|
Equipment cabling subsystem |
Part of the cabling structure, typically between the distribution
frame and the equipment.
Hits - 1074
|
Equipment room (ER) |
A centralized space for telecommunications equipment
that serves the occupants of the building or multiple
buildings in a campus environment. Usually considered
distinct from a telecommunications closet because it is
considered to serve a building or campus; the telecommunications
closet serves only a single floor. The equipment
room is also considered distinct because of the nature of
complexity of the equipment that is contained in it.
Hits - 1451
|